The Casa GH2CA is a 30cm domino gas on glass cooktop with two burners: a 10.8 MJ/h (3.0 kW) rapid burner and a 4.3 MJ/h auxiliary burner, for a total gas input of 15.1 MJ/h. It measures 300 x 520 x 100mm (W x D x H) and fits a 262 x 480mm benchtop cut-out.
Every burner has automatic electronic ignition and a flame failure device, which shuts off the gas if the flame goes out. To light a burner, press in and turn the knob, then keep it held in for 15 seconds once the flame has lit.
It suits natural gas (1.0 kPa) or Universal LPG (2.75 kPa), and comes with a gas regulator, a pressure test point and 2 injectors. The ignition runs from a power cord with a 10A plug, and the cooktop must be installed by a licensed gas fitter.
Key Functions & Features- 10.8 MJ/h (3.0 kW) rapid burner
- 4.3 MJ/h (≈1.2 kW) auxiliary burner
- Total gas input of 15.1 MJ/h
- 30cm domino format with a black glass top
- Automatic electronic ignition
- Flame failure device on both burners
- Natural gas or Universal LPG, with injectors and gas regulator supplied
- Fits a 262 x 480mm benchtop cut-out
-
Height (mm)100 mm
-
Width (mm)300 mm
-
Depth (mm)520 mm
-
Cut Out Depth (mm)480
-
Cut Out Width (mm)262
-
Model numberGH2CA
-
ColourBlack
-
Cooking zones2
-
Product fuelGas
-
Features✓ 10.8 MJ/h (3.0 kW) rapid burner ✓ 4.3 MJ/h (≈1.2 kW) auxiliary burner ✓ 30cm domino format with black glass top ✓ Automatic electronic ignition ✓ Flame failure device on both burners ✓ Natural gas or Universal LPG, injectors supplied
-
Manufacturer warranty2 Years
-
More SpecsGeneral
- Type: 30cm Domino Gas on Glass Cooktop
- Top Plate: Black glass
- Ignition: Automatic electronic ignition
- Flame Failure Device: Every burner
- Included: 2 brackets, 2 screws, 2 seals, 2 injectors, gas regulator, pressure test point, elbow, auxiliary pan support, instruction manual
- Rapid Burner: 10.8 MJ/h (3.0 kW)
- Auxiliary Burner: 4.3 MJ/h (≈1.2 kW)
- Total Gas Input: 15.1 MJ/h
- Recommended Pan Sizes: Rapid 200–220mm; auxiliary 120–160mm
- Gas Type: Natural gas 1.0 kPa or Universal LPG 2.75 kPa
- NG Injectors (mm): Rapid 1.50, auxiliary 0.93
- ULPG Injectors (mm): Rapid 0.90, auxiliary 0.58
- Gas Connection: G1/2 thread
- Hose: AS/NZS 1869, 10mm ID, class B or D, max. 1.2m
- Supply: 220–240V~ 50–60Hz
- Power: 2W (ignition)
- Connection: Power cord with 10A plug
- Earthing: Must be earthed
- Pot Support Height Above Bench: 47.5mm
- Clearance Above: 650mm to range hood or surface
- Side / Rear Wall: 60mm min.
- Gap Below Hob: 25–74mm